Adresse:9 / F, Bâtiment 20, Parc industriel de la science et de la technologie Arex, 19 Road East Huifeng, Zone de haute technologie de Zhongkai, Ville de Huizhou, Province du Guangdong
Adresse:9 / F, Bâtiment 20, Parc industriel de la science et de la technologie Arex, 19 Road East Huifeng, Zone de haute technologie de Zhongkai, Ville de Huizhou, Province du Guangdong
19 Onduleur à onde sinusoïdale monté en rack en pouces, 110 V CC à 120 V CA 3000 Onduleur à onde sinusoïdale Watt
Voir plus de photos
Description:
The pure sine wave DT-1000 Series inverters are BWITT new expand customize inverter. This Series is a professional 19” rack enclosure with a wide range of options to suit applications.
19 Onduleur à onde sinusoïdale monté en rack en pouces, 110 V CC à 120 V CA 3000 Onduleur à onde sinusoïdale Watt
Product Description:
The pure sine wave DT-1000 Series inverters are BWITT new expand customize inverter. This Series is a professional 19” rack enclosure with a wide range of options to suit applications.
This type Rack mount Inverter with a new generation of dual input inverter solution designed for the field of communication applications, qui convient à la haute fiabilité du système de communication. The solution is equipped with 120V AC power supply and 110V DC power Input , qui comble l'écart entre l'alimentation UPS traditionnelle et les solutions d'onduleur à ondes sinusoïdales courantes.
Product Feature:
Standard 19” Rack mount2 RUChassis;
True sine wave output (T.H.D < 3%);
Large 128*64 Digital LCD Afficher les informations sur les données,4 affichage LED fonctionnant;
5 Itinéraire le contact sec pour le système (Défaut d'entrée CC, Fauteur d'entrée CA, Informations de surcharge, Informations de contournement et défaut de sortie);
RS232 and RS485 & Port de communication SNMP en option;
Power-on self-test, Démarrage de sortie souple,Start auto restart while Ac or Dc is recovering;
Auto switch function: DC à AC, Contournement AC, Moins de 5 ms;
Real-time monitoring of the system operating status,Audible and visual alarm;
Record the historical alarm message and can be queried;
Build in voltage regulator Stabilize AC voltage;
Maintenance bypass /DC available;
Protection :Protection de la charge courte, Protection de chargement, Protection de tension de batterie sur / sous, sur le courant, sur la température;
About us:
Balises:
Modèle
BWT110/120-3Kva
INPUT
AC Input Voltage
98~144 VAC (120V Norm)
Battery Input Voltage
110VDC
Battery Voltage Range
104Vdc—145Vdc
Cutoff Voltage
<90 or >150Vdc
Cooling
4*Fans (Temp.Control Speed According to the output Capacity)
DC Input Current
28.84 Max
Fréquence de sortie
60Hz±0.1%
PF
0.8
OUTPUT
Output Capacity
3000Virginie
Rated Output Capacity
2400W
Rated output Voltage
120Vaccin (Inverter Mode)
Rated Output Current
20UN
Output Voltage Range
120Vaccin(Tolerance ±1.5% @Inverter Mode)
Output Efficiency
85~ 90% (Inverter Mode)
Fréquence de sortie
60HZ
Frequency Range
57~63Hz
Output Wave
Onde sinusoïdale pure
THD
≤3% (Line Load)
Switch Time (By pass to Inverter mode)
≤5ms (With Load)
PROTECTIVE FEATURE
AC Under Voltage Switch Protection
≤90Vac (Backlash voltage≥10Vac)
AC over Voltage Switch protection
≥155AC
Over-Temperature
Oui (Auto Switch)
Battery under voltage protection point
≤90
Battery Low-voltage alarm
90±0.5
Battery overvoltage protection point
≥155VDC
Battery overvoltage recovery point
≥145VDC
Output Over Current Protection
Over Load Capacity
Continue working @overload 110%
Over Load Capacity
Continue working 60s @ overload 110%~130%
Over Load Capacity
Continue working 10s @over load >150%
Over Temp. Protection
Oui
short circuit Protection
Oui (Don’t test under AC Connect)
Reverse connection protection
Oui
Output OVP
≥145VAC(Inverter Mode)
Output low voltage alarm
≤90VAC (Inveter Mode)
SAFETY AND EMC
Dielectric strength(AC-Chassis)
3500Vdc/10mA//1min .No flash over, no breakdown, no arc (Only AC Input priority)
Dielectric strength(DC-Chassis)
750Vdc/10mA/1min. No flash over, no breakdown
LVD
EN 60950-1
EMC/EM I